hwdro fc19d9d11b obs-filters: Fix noise-gate calculation errors
For both cases the cur_level calculations were "wrong". For one channel
case, I assume that was only an oversight, as for two channels case
cur_level "calculation", getting the level from downmixing to mono will
result in an attenuated level than expected. One solution is to use the
highest level of both channels to drive the gate.