This file is fairly incomplete. Read the code if this is not enough. Help is welcome.
|
|
|
|
Tiers
|
|
-----
|
|
The tier is a string, currently `"LV"`, `"MV"` and `"HV"` are included with technic.
|
|
|
|
Network
|
|
-------
|
|
The network is the cable with the connected machine nodes. The switching station activates network.
|
|
|
|
Helper functions
|
|
----------------
|
|
* `technic.EU_string(num)`
|
|
* Converts num to a human-readable string (see pretty_num)
|
|
and adds the `EU` unit
|
|
* Use this function when showing players energy values
|
|
* `technic.pretty_num(num)`
|
|
* Converts the number `num` to a human-readable string with SI prefixes
|
|
* `technic.swap_node(pos, nodename)`
|
|
* Same as `mintest.swap_node` but it only changes the nodename.
|
|
* It uses `minetest.get_node` before swapping to ensure the new nodename
|
|
is not the same as the current one.
|
|
* `technic.get_or_load_node(pos)`
|
|
* If the mapblock is loaded, it returns the node at pos,
|
|
else it loads the chunk and returns `nil`.
|
|
* `technic.is_tier_cable(nodename, tier)`
|
|
* Tells whether the node `nodename` is the cable of the tier `tier`.
|
|
* `technic.get_cable_tier(nodename)`
|
|
* Returns the tier of the cable `nodename` or `nil`.
|
|
* `technic.trace_node_ray(pos, dir, range)`
|
|
* Returns an iteration function (usable in the for loop) to iterate over the
|
|
node positions along the specified ray.
|
|
* The returned positions will not include the starting position `pos`.
|
|
* `technic.trace_node_ray_fat(pos, dir, range)`
|
|
* Like `technic.trace_node_ray` but includes extra positions near the ray.
|
|
* The node ray functions are used for mining lasers.
|
|
* `technic.tube_inject_item(pos, start_pos, velocity, item)`
|
|
* Same as `pipeworks.tube_inject_item`
|
|
|
|
Configuration API
|
|
----------------------
|
|
* `technic.config` Settings object that contains Technic configuration.
|
|
* Provides all methods that are provided by Minetest Settings object.
|
|
* Uses `<world-path>/technic.conf` as configuration file.
|
|
* If key is not present in configuration then returns default value for that key.
|
|
* `:get_int(key)` Return number value for configuration key.
|
|
|
|
Power tool API
|
|
----------------------
|
|
|
|
* `technic.register_power_tool(itemname, definition)`
|
|
* Registers power tool adding required fields, otherwise same as `minetest.register_tool(itemname, definition)`.
|
|
* For regular power tools you only want to change `max_charge` and leave other fields unset (defaults).
|
|
* Special fields for `definition`:
|
|
* `technic_max_charge` Number, maximum charge for tool. Defaults to `10000` which is same as RE battery.
|
|
* `on_refill` Function to refill charge completely. Default is to set maximum charge for tool.
|
|
* `wear_represents` Customize wear indicator instead of using charge level. Default is `"technic_RE_charge"`.
|
|
* `tool_capabilities` See Minetest documentation. Default is `{ punch_attack_uses = 0 }`.
|
|
* `technic_get_charge = function(itemstack) ...`:
|
|
* Callback will be used to get itemstack charge and max\_charge.
|
|
* Have to return values `charge, max_charge`.
|
|
* Etc. `local charge, maxcharge = itemdef.technic_get_charge(itemstack)`.
|
|
* Defaults to `technic.get_RE_charge` which handles tool wear and charge values.
|
|
* `technic_set_charge = function(itemstack, charge) ...`:
|
|
* Callback will be used to set itemstack charge.
|
|
* Defaults to `technic.set_RE_charge` which handles tool wear and charge values.
|
|
* `technic.get_RE_charge(itemstack)`
|
|
* Returns current charge level of tool.
|
|
* For tool charger mods it is recommended to use `<tooldef>.technic_get_charge(stack)` instead.
|
|
* `technic.set_RE_charge(itemstack, charge)`
|
|
* Sets tool charge level.
|
|
* For tool charger mods it is recommended to use `<tooldef>.technic_set_charge(stack, charge)` instead.
|
|
* `technic.use_RE_charge(itemstack, charge)`
|
|
* Attempt to use charge and return `true`/`false` indicating success.
|
|
* Always succeeds without checking charge level if creative is enabled.
|
|
|
|
Machine registration API
|
|
----------------------
|
|
* `technic.register_machine(tier, nodename, machine_type)`
|
|
* Custom machine registration. Not needed when using builtin machine registration functions.
|
|
* See also `Machine types`
|
|
* `technic.register_tier(tier)`
|
|
* Registers network tier.
|
|
* See also `tiers`
|
|
* `technic.register_base_machine(nodename, def)`
|
|
* Register various types of basic factory processing machines.
|
|
* `typename = "compressing"`
|
|
* `description = S("%s Compressor")`
|
|
* `tier = "HV"`
|
|
* `demand = {1500, 1000, 750}`
|
|
* `speed = 5`
|
|
* `upgrade = 1`
|
|
* `tube = 1`
|
|
* TODO / TBD
|
|
* `technic.register_solar_array(nodename, def)`
|
|
* Registers solar array generator.
|
|
* `tier = "HV"`
|
|
* `power = 100`
|
|
* TODO / TBD
|
|
* `technic.register_battery_box(nodename, def)`
|
|
* Registers battery box node used as energy storage.
|
|
* TODO / TBD
|
|
* `technic.register_cable(nodename, data)`
|
|
* Registers technic network cables.
|
|
* `tier = "HV"`
|
|
* `size = 3/16`
|
|
* `description = S("%s Digiline Cable"):format("HV")`
|
|
* `digiline = { wire = { rules = technic.digilines.rules_allfaces } }`
|
|
* `technic.register_cable_plate(nodename, data)`
|
|
* Registers technic network cable plates. Results in multiple nodes registered with `_1` to `_6` appended to name.
|
|
* See `technic.register_cable(nodename, data)`
|
|
|
|
Network control API
|
|
----------------------
|
|
* TBD, functions exported through technic namespace are currently considered to be internal use only.
|
|
|
|
### Specific machines
|
|
* `technic.can_insert_unique_stack(pos, node, stack, direction)`
|
|
* `technic.insert_object_unique_stack(pos, node, stack, direction)`
|
|
* Functions for the parameters `can_insert` and `insert_object` to avoid
|
|
filling multiple inventory slots with same type of item.
|
|
|
|
Used itemdef fields
|
|
----------------------
|
|
* groups:
|
|
* `technic_<ltier> = 1` ltier is a tier in small letters; this group makes
|
|
the node connect to the cable(s) of the right tier.
|
|
* `technic_machine = 1` Currently used for
|
|
* `connect_sides`
|
|
* In addition to the default use (see lua_api.txt), this tells where the
|
|
machine can be connected.
|
|
* `technic_run(pos, node)`
|
|
* This function is currently used to update the node.
|
|
* `wear_represents = "string"`
|
|
* Specifies how the tool wear level is handled. Available modes:
|
|
* `"mechanical_wear"`: represents physical damage
|
|
* `"technic_RE_charge"`: represents electrical charge
|
|
* `<itemdef>.technic_run = function(pos, node) ...`
|
|
* This callback is used to update the node.
|
|
* `<itemdef>.technic_disabled_machine_name = "string"`
|
|
* Specifies the machine's node name to use when it's not connected connected to a network
|
|
* `<itemdef>.technic_on_disable = function(pos, node) ...`
|
|
* This callback is run when the machine is no longer connected to a technic-powered network.
|
|
|
|
Machine types
|
|
-------------
|
|
There are currently following types:
|
|
* `technic.receiver = "RE"` e.g. grinder
|
|
* `technic.producer = "PR"` e.g. solar panel
|
|
* `technic.producer_receiver = "PR_RE"` supply converter
|
|
* `technic.battery = "BA"` e.g. LV batbox
|
|
|
|
Switching Station
|
|
-----------------
|
|
The switching station is required to start electric network and keep it running.
|
|
Unlike in original mod this node does not handle power distribution logic but instead just resets network timeout.
|
|
|
|
Network logic
|
|
-----------------
|
|
|
|
The network logic collects power from sources (PR), distributes it to sinks (RE),
|
|
and uses the excess/shortfall to charge and discharge batteries (BA).
|
|
|
|
For now, all supply and demand values are expressed in kW.
|
|
|
|
All the RE nodes are queried for their current EU demand. Those which are off would
|
|
require no or a small standby EU demand, while those which are on would require more.
|
|
If total demand is less than the available power they are all updated with the demand number.
|
|
If any surplus exists from the PR nodes the batteries will be charged evenly with excess power.
|
|
If total demand exceeds generator supply then draw difference from batteries.
|
|
If total demand is more than available power all RE nodes will be shut down.
|
|
|
|
### Node meta usage
|
|
Nodes connected to the network will have one or more of these parameters as meta data:
|
|
* `<LV|MV|HV>_EU_supply` : Exists for PR and BA node types. This is the EU value supplied by the node. Output
|
|
* `<LV|MV|HV>_EU_demand` : Exists for RE and BA node types. This is the EU value the node requires to run. Output
|
|
* `<LV|MV|HV>_EU_input` : Exists for RE and BA node types. This is the actual EU value the network can give the node. Input
|
|
|
|
The reason the LV|MV|HV type is prepended to meta data is because some machine
|
|
could require several supplies to work.
|
|
This way the supplies are separated per network.
|