43682a8c3e
Specifically, AL_[EAX]REVERB_ROOM_ROLLOFF_FACTOR always applies to an inverse distance rolloff model, where the source's AL_ROOM_ROLLOFF_FACTOR applies to the selected distance model. Consequently, the normal distance and cone attenuation only needs to be calculated once for all sends, with the effect's room rolloff calculated and applied separately.