improve ta4 sensor box
This commit is contained in:
parent
dcb06e210e
commit
c4e431b46e
@ -1,6 +1,5 @@
|
||||
# textdomain: techage
|
||||
|
||||
ku is needed!)=
|
||||
#### TA3 Terminal ####@n@nSend commands to your machines@nand output text messages from your@nmachines to the Terminal.@n@nCommand syntax:@n cmd <num> <cmnd>@n@nexample: cmd 181 on@n<num> is the number of the node to which the command is sent@n'on' is the command to turn machines/nodes on@nFurther commands can be retrieved by clicking on@nmachines/nodes with the Techage Info Tool.@n@nLocal commands:@n- clear @= clear screen@n- help @= this message@n- pub @= switch to public use@n- priv @= switch to private use@nTo program a user button with a command:@n set <button-num> <button-text> <command>@ne.g. 'set 1 ON cmd 123 on'@n=
|
||||
Accu Box=Akkublock
|
||||
Active:=Aktiv:
|
||||
@ -430,6 +429,7 @@ inlet/pipe error=Einlass/Röhrenfehler
|
||||
inventory full=Inventar ist voll
|
||||
item output blocked=Ausgang blockiert
|
||||
keep assignment=Zuordnung beibehalten
|
||||
ku is needed=ku wird benötigt
|
||||
light=Licht
|
||||
loaded=geladen
|
||||
needs power=benötigt Strom
|
||||
@ -454,4 +454,4 @@ water temperature=Wassertemperatur
|
||||
wrong catalyst=falscher Katalysator
|
||||
wrong storage diameter=Falscher Wärmespeicher-Durchmesser
|
||||
##### not used anymore #####
|
||||
ku is needed!)= ku wird benötigt!)
|
||||
|
||||
|
@ -1,4 +1,3 @@
|
||||
ku is needed!)=
|
||||
#### TA3 Terminal ####@n@nSend commands to your machines@nand output text messages from your@nmachines to the Terminal.@n@nCommand syntax:@n cmd <num> <cmnd>@n@nexample: cmd 181 on@n<num> is the number of the node to which the command is sent@n'on' is the command to turn machines/nodes on@nFurther commands can be retrieved by clicking on@nmachines/nodes with the Techage Info Tool.@n@nLocal commands:@n- clear @= clear screen@n- help @= this message@n- pub @= switch to public use@n- priv @= switch to private use@nTo program a user button with a command:@n set <button-num> <button-text> <command>@ne.g. 'set 1 ON cmd 123 on'@n=
|
||||
Accu Box=
|
||||
Active:=
|
||||
@ -428,6 +427,7 @@ inlet/pipe error=
|
||||
inventory full=
|
||||
item output blocked=
|
||||
keep assignment=
|
||||
ku is needed=
|
||||
light=
|
||||
loaded=
|
||||
needs power=
|
||||
|
@ -193,7 +193,7 @@ local function get_state(netw)
|
||||
if #(netw.gen1 or {}) + #(netw.gen2 or {}) == 0 then
|
||||
state = S("No power grid or running generator!")
|
||||
elseif needed > (netw.available1 or 0) then
|
||||
state = S("Probably too many consumers (")..needed..S(" ku is needed!)")
|
||||
state = S("Probably too many consumers (")..needed.." "..S("ku is needed").."!)"
|
||||
elseif (netw.num_nodes or 0) < techage.networks.MAX_NUM_NODES then
|
||||
state = S("Number of power grid blocks")..": "..(netw.num_nodes or 0)..", "..S("Max. needed power")..": "..needed.. " ku"
|
||||
else
|
||||
|
Loading…
x
Reference in New Issue
Block a user